Polyethylene without additives is a grade that can easily degrade when
exposed to the environment. UV light generated by the sun can quickly affect
the molecular structure of the part as the light penetrates into the material
and starts breaking the molecular chains. As the molecular chains break
the part weakens to the point where the material can turn into dust. A
typical additive used to protect outdoor applications is carbon black.
In most applications, carbon black in concentrations of 3% or more are
known to protect HDPE from the sun. |
| An analytical test that can be used to detect degradation is the FTIR
(Fourier Transform Infrared Spectroscopy). FTIR spectroscopy was performed
at the surface and core of the HDPE sample. The FTIR shows the typical
spectral results expected for polyethylene. However, the spectral shows
two additional absorption bands (one between 1750 cm-1 and 1700 cm-1, and
another between 1300 cm-1 and 1100 cm-1) that indicate the formation of
carbonyls and byproducts associated with oxidation. The FTIR performed
at the surface of the part shows stronger absorption bands compared to
the FTIR at the core. Therefore, the level of oxidation at the surface
is much higher than the oxidation at the core of the part. The large difference
between oxidation at the surface and core is typical of degradation caused
by ultraviolet light, as opposed to thermal degradation, which tends to
degrade a material uniformly through the thickness. |
 |
Further, a melt flow rate (MFR) test was performed to get a qualitative
idea of the molecular weight of the part. The melt flow rate for the failed
part was higher than 150 grams/10 minutes. The material specified for this
application was an HDPE with MFR of 15. This large difference between specified
and tested MFR is due to the molecules breaking because of material degradation.
As the molecules break, the molecular weight drops dramatically, thus the
melt flow rate increases. The MFR test was further evidence of material
degradation, confirmed to be consequence of UV light by the FTIR.
Corrective Action: the corrective action recommended for
this application was to improve the UV stabilization package.
|